C6KR
PRICE : PLEASE CALL
(not include VAT)
Santak C6KR UPS has a 19″ Rackmount form, suitable for Rack cabinets, is arranged in common with Servers in the cabinet, creating a complete system that ensures the technical and aesthetic of the standard Santak C6KR UPS system including 02 modules. , one module contains the processor and one module contains the battery.For longer battery backup needs, customers can purchase additionally 01 or maximum 2 battery modules to be added to the system to increase the backup time. .
INSERT SOURCE | |
---|---|
Nominal voltage | 220 VAC |
Voltage threshold | 176 ~ 276 VAC |
Phase number | 1 phase (2 wires + ground wire) |
Nominal frequency | 50 Hz (46 ~ 54 Hz) |
Power Factor | ≥ 0.98 |
Generator compatible | Yes |
SOURCE | |
Capacity | 6 KVA / 4.2 KW |
Voltage | 220 VAC ± 1% |
Phase number | 1 phase (2 wires + ground wire) |
Waveform | True sine wave in all grid states and independent of the remaining capacity of the battery source. |
Frequency | 50 Hz ± 0.05Hz |
Performance | 88% (Grid, battery mode) |
Overload tolerance | ≥ 105% in 10 minutes |
Output power supply | 4 IEC320-10A sockets and terminal block |
Automatically switch to Bypass mode | Overload, UPS failure, low battery level |
Service Switch | No |
ẮQUI | |
Battery type | 12 VDC, airtight, maintenance-free, over 3 years lifespan. |
Save time | 7 minutes at 100% load, 20 minutes at 50% load |
Battery charge time | 8 hours to 90% of battery capacity |
EASY INTERFACE | |
Dashboard | Start button / Siren off / Power off button |
Status LED | Grid power mode, battery mode, Bypass mode, load capacity, battery capacity, failure status alarm. |
Communication port | RS232, smart slot |
Management software | Power management software and automatic shutdown Winpower/ Webpower |
Switching time | 0 ms |
N+X parallel connection function | No |
OPERATING ENVIRONMENT | |
Operating ambient temperature | 0 ~ 40oc |
Operating ambient humidity | 20% ~ 90%, no condensation. |
Cooling system | Air convection fan |
STANDARDS | |
Noise when operating | 55 dB excluding siren |
Electromagnetic field (EMS) | IEC 61000-4-2 Level 4 (ESD) |
IEC 61000-4-3 Level 3 (RS) | |
IEC 61000-4-4 Level 4 (EFT) | |
IEC 61000-4-5 Level 4 (Surge) | |
EMI safety standard | IEC62040-2, with input current ≥ 25A |
SIZE / WEIGHT | |
Processor size (R x D x C) (mm) | 482.6 x 600 x 130 (3U) 19 inch rackmount |
Net weight (kg) | 18.3 |
Battery pack dimensions (R x D x C) (mm) | 482.6 x 600 x 130 (3U) 19 inch rackmount |
Net weight (kg) | 58.2 |