Follow Us

Santak UPS – Item code 75KVA Frame

  • Giá: 240439700 VNĐ
Mua Ngay

75KVA-FRAME
UNIT PRICE : 240,439,700 VND
(not include VAT)
Batteries not included – Frame contains 25KVA Santak Online UPS modules, the optimal solution for multi-stage redundancy systems that allows mounting from 1 to 3 UPS Modules 25KVA with a maximum system capacity of up to 75KVA. Power saving time can be customized according to customer requirements.

 

MODEL ARRAY 3A3PT 25-75K 
Technology Double conversion on-line technology,
three-level bridge IGBT PWM control
INSERT SOURCE
Nominal voltage 220/380Vac, 230/400Vac, 240/415Vac
Voltage threshold 214 – 520 Vac (L-L)
Phase number 3 phase, 4 wire + ground wire (3ph + N + PE)
Nominal frequency 50Hz or 60Hz, User configurable
Power Factor ≥ 0.99
Generator compatible Yes
OUTSOURCE
Capacity 25kVA-200kVA, 0.9pf
Voltage 220/380Vac, 230/400Vac, 240/415Vac Configurable
Phase number 3 phase, 4 wire + ground wire (3ph + N + PE)
Waveform True sine wave in all grid states and independent of the remaining capacity of the battery source.
Frequency 50/60Hz±0.1Hz
Load concatenation type 3 phase (Star form – 4 wires + ground wire)
Performance 96% (Dual conversion mode)

99% (ECO mode)

BYPASS MODE
Automatically switch to Bypass mode Overload, UPS failure
Service Switch Available
ẮC QUI
Battery type 12 VDC, airtight, maintenance free
Save time Depending on the capacity of the external battery – Customers choose according to their needs and costs
Battery charge time Depending on external battery capacity
interface
Dashboard Provides easy access to detailed operational status information via the large 7” HMI touch screen, user-friendly
Status LED Grid power mode, battery mode, Bypass mode, load capacity, battery capacity, failure status alarm.
Communication port RS232, USB, Minislot (3), Building Alarm inputs, EPO
Management software Winpower system automatic shutdown and power management software compatible with Window, Linux, Unix, Sun
Switching time 0 ms
Emergency shutdown function (EPO) Yes
Extended parallel connection Up to 4 systems. Total system capacity up to 300kVA
OPERATING ENVIRONMENT
Operating ambient temperature 5 ~ 40oC
Operating ambient humidity 5 ~ 95%, no condensation
STANDARD
Noise when operating < 65dB in double conversion mode
Safety IEC 62040-1, IEC 60950-1
EMC, Emissions IEC 62040-2 2005
Electromagnetic field (EMS) IEC 61000-2-2 (Low-frequency practice)
IEC 61000-4-2 (ESD)
IEC 61000-4-3 (RF electromagnetic field)
IEC 61000-4-5 (Surge)
IEC 61000-4-6 (Conducted RF common mode)
IEC 61000-4-8 (Power frequency magnetic field)
EMI conductivity and emission IEC 6204-3
SIZE / WEIGHT
Dimensions (R x D x C) (mm) 608 x 1100 x 2020
Weight